Get Ready to Pass the PVIP exam Right Now Using Our NABCEP Board Exam Package [Q10-Q24]

4.4/5 - (7 votes)

Get Ready to Pass the PVIP exam Right Now Using Our NABCEP Board Exam Package

Enhance Your Career With Available Preparation Guide for PVIP Exam

Achieving NABCEP PVIP certification is a significant accomplishment for individuals working in the solar industry. It demonstrates their commitment to professionalism, safety, and quality in their work. PV Installation Professional (PVIP) Board Certification certification is recognized by the industry as the gold standard for PV installation professionals and is often required by employers and government agencies for certain types of projects. Additionally, NABCEP certified professionals are listed in a national registry, which helps potential customers and employers identify qualified individuals for their solar energy needs.

NABCEP PVIP Certification Exam is designed to test an individual’s knowledge and skills in the installation of photovoltaic (PV) solar systems. PV Installation Professional (PVIP) Board Certification certification is recognized as the gold standard in the solar industry, and it is often required by employers and government agencies for certain solar-related jobs. PVIP exam covers a wide range of topics, including safety, design, installation, and maintenance of PV systems.

 

NO.10 A homeowner is concerned that a 6kWdc PV system might be experiencing a performance issue. The homeowner has noticed what appears to be declining production. The installer analyzes the following data acquisition system (DAS) results for each year since the installation:

Given the data, which is the MOST likely conclusion to draw?

 
 
 
 

NO.11 An installer is using ½ in lag boits to secure roof-monitoring hardware to rafters through a roof deck. Which of the following should the installer predrill?

 
 
 
 

NO.12 A PV system’s capacity factor is 18%. The array is 10 kW, and it operates 365 days/year. What is the annual energy output?

 
 
 
 

NO.13 When doinginitial inspections on a PV system that was installed using racking that is not compliant with UL.2703, an inspector should pay special attention to which electrical attribute?

 
 
 
 

NO.14 A project is using a PV module with a 25-38dc maximum power voltage range and a single input inverter with an operating windows of 250vdc-450dc. The dwelling the system is to be installed on has a 5:12 roof with a southeastem face that can accommodate 14 modules and southwestern face that can accommodate 10 modules. What is the MAXIMUM number of modules that can be installed for proper inverter maximum power point tracking?

 
 
 
 

NO.15 A ground-fault protection device (GFPD) trips during commissioning. What is the most likely cause per NEC 690.5?

 
 
 
 

NO.16 A grid-interactive PV system with battery backup is being installed with a ground-mounted PV array located
200 ft, from the inverter and batteries. The dc PV output circuit has overcuit has overcurrent protection rated from 30A. To reduce voltage drop between the array and batteries, the output circuit wire size was determined to be 6 AWG. The fused dc disconnect between the inverted and batteries is rated for 300A. What is the required size of the equipment grounding conductor between the metal battery case and the inverter?

 
 
 
 

NO.17 When performing a system checkout after completing the installation, what is the SAFEST sequence of tasks to detect installation errors before closing any disconnects to the inverter, charge controller, or batteries?

 
 
 
 

NO.18 A 1. 100 ft, 2 ranch home with cathedralcallingshas a 14 ft. x 41 ft. 8 in , south-facing , composite shingle roof. An engineer has determined that the home’s 2 in, x 6 in. on-center roof rafters are strong enough to gold a solar electric system. The system will have 62.25 in. x 32.50 in. modules with a 1-in gap between modules and a standard twin-rillmounting system number of modules that can fit on the roof on under these conditions?

 
 
 
 

NO.19 Which of the following requires a UL listing or its equivalent?

 
 
 
 

NO.20 An installer was asked to provide a means to measure the voltage of each battery in a system. The bank is located 50 ft.
From the data logger. The installer will be using shielded. Twisted pairs of instrumentation wiring, all run in the bundle a conduct.
The signals are connected to isolated and ungrounded inputs at a data logger. Which safely precaution is MOST needed to protect the instrumentation wiring?

 
 
 
 

NO.21 A PV system interconnects at a 480V three-phase service. The inverter output current is 20A per phase. What is the minimum size of the equipment grounding conductor (EGC) per NEC 250.122 if the OCPD is 30A?

 
 
 
 

NO.22 During a PV system inspection, an installer notices that the rapid shutdown system fails to de-energize the array within 30 seconds of initiation. What is the most likely cause based on NEC 690.12 requirements?

 
 
 
 

NO.23 When commissioning a PV system, which test is most critical to verify proper operation of the array before connecting to the inverter?

 
 
 
 

NO.24 Which insulation color is allowed for a current-carrying roottop dc conductor on a functionally grounded 6kw PV system?

 
 
 
 